Histology Mictrotomes

£0.00

The Rotary Microtome instrument has been designed for the cutting of human and animal tissues embedded in paraffin.

The thickness of the sections can be adjusted according to the tissue type easily by the laboratory technician.

Increased instrument life time and efficiency has been achieved by using special ball bearings for linear and rotating mechanisms.

The Microtome holds two micro and macro handles. The Micro Handle cuts the tissue and the Macro handle moves the specimen rapidly toward the blade.

The section Thickness could be set via the front panel and the volume key from 1 to 60 microns by the operator.

Auto Trim is a facility of the device which could be used via the lever in two modes. The first mode of the system is 10 microns and the second one is 30 microns. This facility makes the operator be able to reach the tissue surface without touching the micron setting volume. For serial and consecutive sections, the Retraction facility is considered on this device.

The specimen clamp is designed in a way that the Standard Parffin Block or  Tissue Embedding Cassette clamps could be installed easily on it and the different Plastic or conventional Paraffin Blocks could be used by them.

The Blade holder consists of two parts and the whole collection could be set according to the blade type from 0 to 10 degrees angle to the specimen.

This part is designed in a way that different types of the knives or the disposable blade holders could be easily .

Clear

Fully Automated Microtome DS9502

Technical Details

Use of the LCDs and Standard graphic signs in the External and Internal panel for the ease of operation

Ease of operation because of avoiding complex and multiple menus; the operator can use all facilities of the system with a simple menu easily

üUse of the most recent technologies of the world in designing and implementation of the hardware and software system

Categorizing all of the probable errors and displaying them on the LCD

General Logging of the performance of the system and the system elements

The hand wheel is designed in a unique way that there is no other similar hand wheel all over the world and no risk threatens the operator while automatic operation of the device

and implementation of the sectioning windows in conformity to the size of the pathological tissues: Surgical and Biopsy tissues.

Modular design and implementation of the specimen holder and the blade holder so the specimen holder part could hold paraffin standard blocks or the tissue cassette molds easily

üThe right use of the cutting operands for the operators in four discrete states like SING, STEP, CONT and No.?

The design has two control panels one of them is placed on the device and the other one is connected to the device externally. Both of them work independently and negotiate with the device in a Real Time manner

Specifications

  • The capability of accurate settings of the cutting speed using the selection volume.
  • 20 levels of speed.
  • The capability of sectioning and trimming in toggling manner through External and Internal keyboards and also via the foot pedal.
  • The thickness of Sectioning range  set from 0.5 to 60 microns
  • Trimming range set from 1 to 600 microns.
  • Optional retraction range set from 5 to 200 microns.
  • The ability to guide the tissue block to a designated point automatically, this function can be activated by the operator.

 

 

Semi Automated Microtome DS9209

Specifications and Technical Data

The system operates in a motorized manner and except the micro handle the other motions are controlled by motor and via the control panel.

The specimen clamp could go ahead and back both rapidly and slowly in course feed of the device.

Controlling the front and back coarse feed automatically by accurate control of the sensors.

The device is controlled and managed in real time manner using two panels

The device system is equipped with Retraction (RET) facility which is be activated would lead to the consecutive sectioning.

The device Trimming (TRM) system could be set to decrease the time of accessing the surface of the tissue which is a very functional process for the crowded centres.

Home position: This position makes the operator able to lead the specimen clamp to the primary position by touching the button.

Retraction (RET) of this system could be turned on or off and could also be set by the operator in 1 to 100 micron limits.

The Trimming (TRM) value could be set by the operator from 2 to 600 micron by the following steps:

2 micron increments for 2-10 micrometer

5 micron increments for 10-20 micrometer

10 micron increments for 20-50 micrometer

50 micron increments for 50-100 micrometer

100 micron increments for 100-600 micrometer

Capability of counting the section numbers on the display panel and the capability of clearing the counted numbers using the CLEAR key

Utilizing the micro-processor controlling system in device settings

The display panel type is Graphite LCD the information related o the settings of the device could be read and observed easily

The double operating system of the device is provided on the device case and also as a side one as an External controller by which the operation of the keys and the settings and also observation of the numbers happen easily.

Specification

  • Sectioning Thickness Settings by the operator:
    • 0.5 micron increments for 0.5-5 micrometer
    • 1 micron increments for 5-20 micrometer
    • 10 micron increments for 20-60 micrometer
  • Equipped with the Universal clamp for accurate settings of the tissue angel to the blade
  • The possibility of changing the blade angel by the operator from 0 to 10 degrees
  • The system is equipped with the emergency key by which the operator can stop the system operation immediately

Rotary Microtome DS8402

Specifications:

  • Modular design
  • Mechanical system
    • No gear is used in this device for controlling the specimen feed so the device operates with high accuracy for long time.
  • The plastic tissue container Clamp could be installed easily
  • Section thickness ranges from 1 to 60 microns
  • The angle of the blade could be set from 0 to 10 degrees to the specimen or the paraffin block by the operator
  • Equipped with Micron handle lock in all rotational situations
  • Ease of operation
  • The specimen could be rapidly moved through the blade by a Macro handle
  • Use of the special Ball Bearings in moving parts of the device to prevent the rapid amortization of the device
  • Equipped with Automatic Retraction System for serial sectioning
  • Equipped with Trimming Stage in 10 and 30 microns for faster trimming allowing the operator reach the tissue surface quickly
  • The device weighs approximately 34 kilograms

Rotary Microtome DS4055

Specifications:

  • Fully Mechanic and Modular System
    • No gear is used in this device for controlling the specimen feed so the device operates with high accuracy for long time.
  • The plastic tissue container Clamp could be installed easily
  • Section thickness ranges from 0.5 to 60 microns
  • The angle of the blade could be set from 5 to 25 degrees to the specimen or the paraffin block by the operator
  • Equipped with Micron handle in all rotational situations
  • Ease of operation
  • The specimen could be rapidly moved through the blade by a Macro handle
  • Use of the special Ball Bearings in moving parts of the device to prevent the rapid amortization of the device
  • Equipped with Automatic Retraction System for serial sectioning
  • The device weighs approximately 37.5 kilograms